Updated on 03/08/2021

Due, in part, to the different views and opinions regarding the usage of hot spare disks in our previous post, we’ve decided to add an update for clarification. 

The Problematic Aspects of Using a Hot Spare Disk

As is said in almost every theory, using a hot spare disk with ZFS, Solaris FMA or in any other data storage environment is a good solution as it will automatically react to damage in a Redundant Array of Independent Disks (RAID) array and a hot spare disk indeed helps to minimize the duration of a degraded array state. 

That being said, our goal of creating a RAID is to continue operation and not lose data in the event of a disk failure. Anything that increases the risk of data loss could be a bad idea. Let’s have a look at some of these problematic aspects of hot spare disks.

Hot Spare Disks Add Stress to Vulnerable Systems

The main problem with hot spare disks is that they allow the rebuilding (resilvering) of a system that is still actively being used as a production server. This means that, while the resilvering process is taking place, the system will also still be occupied with the usual production data reads and writes. 

Resilvering is a process that needs a lot of server resources so when it’s executed while the server is still in use, it has to compete with the production loads. Since it’s a low-priority task, it can make the entire process of resilvering take very long (even up to a few weeks). This results in the server working at maximum achievable throughput for weeks, which can have dire consequences for the disks (especially HDDs).

Having decades worth of experience, we’ve realized that the use of hot spare disks in complex enterprise systems increases the probability of additional disks failing as the resilvering process starts to put more and more stress on the existing disks and the system itself

Problems in Overall Hot Spare Disk Design

The next flaw of a hot spare disk is that it degrades over time. From the moment it is connected to the system, it keeps on working. And when, eventually, it’s time for it to be used as a damaged disk’s replacement; the hot spare disk itself could simply not be in a good enough state to actually replace the damaged disk.

Another problematic aspect of hot spare disks is that they are used automatically once the disk failure is detected so the corrupted disk might still be connected to the system. It could still try to reconnect and start working again while the hot spare disk is trying to take over its role thus adding even more stress to the system. This is yet another factor that can affect the system’s overall performance and could potentially lead to data loss.  

Hot Spare Disks Create a Single Point of Failure

If you’re looking to create a system with no single point of failure, a hot spare disk will not provide you with much confidence given that the process of automatically replacing a failed disk has been known to occasionally fail, either partially or fully, and result in data loss. 

Having spent decades providing customers with data storage solutions, we’ve heard of a lot of examples where a hot spare disk was the reason for the entire server failure and even data loss occurring. Automation here is risky since it can start the domino effect, especially when the data storage infrastructure has been working for years and the hardware is worn out. 

Our Solution

These problematic aspects of hot spare disks are why our advice would be to not rely on hot spare disks in complex data storage architectures and to use other business continuity solutions instead like High Availability (HA) clusters, backups and On- & Off-site Data Protection (ideally all of the aforementioned). 

Using the ZFS file system, it’s much easier to monitor the system and create a proper backup, with that you have the ability to retrieve data from a damaged disk and write it onto a new one. In addition to that, when using a HA cluster, there is an option of manually switching the production from the affected node to a second one so that you could perform maintenance on the affected node. 

We’d advise following this procedure once the array shows that a degraded state has occurred as a result of a disk failure:

  1. Move resources to the second node in your HA cluster if possible.
  2. Run a full data backup.
  3. Verify the backed-up data for consistency, and verify whether the data restore mechanism works.
  4. Identify the problem source, i.e., find the erroneous hard disk. If possible, shut down the server and make sure the serial number of the hard disk matches the one that’s reported by the event viewer or system logs..
  5. Replace the hard disk identified as bad with a new, unused one. If the replacement hard disk had already been used within another RAID array; make sure that any residual RAID metadata on it has been deleted via the original RAID controller.
  6. Start a rebuild of the system.

So, if using this approach, the rebuild would consist of 6 steps! Using a hot spare disk, your RAID will skip the first four significant steps and then automatically run steps 5, and 6. Thus the rebuild will be completed before you can do these other critical steps; steps that could be the difference between your data being safe and lost.

Anyway, it’s still completely up to you as to how to build a proper system. However, we’d suggest not relying on hot spare disks in a ZFS RAID array due to the potential data loss it can cause. 

 

49 Comments

  • Boyan /

    27, 12 2019 04:28:42

    Many of the replies don’t get why is using a Hot-Spare Drive a bad idea, because… it isn’t and the the opinion expressed here is imho is false. Wait so you stay away from high stress events – YES totally correct yet you recommend TWO of them instead of ONE?

    Run full back – the highest stress event possible, then swap the bad HD and let it rebuild – second highest stress event possible instead of letting the hot spare rebuild and end up with ONE and only ONE high stress event on the books? Disagree?

    Reply
    • Michael /

      21, 02 2021 08:31:09

      Boyan, I completely agree with you! Also make note to all of you that the modern server today allows 2-disk fault taulerance which means that if one disk fails one may be inserted for rebuild with minimal stress. Even if a 2nd drive dies during rebuild in the above example, the rebuild will finish and will say ‘You are still in need to insert a 2nd drive to finish rebuild’ after it reaches 100%.

      Have a good week.

      Reply
  • Michael /

    21, 02 2021 08:17:36

    Back in 2010 when this article was posted, I would definitely agree that having a HS is a bad idea. However, today, disk failure during rebuild is much less likely and I have been using Hotspare the last 2 years since 2019 and its worked miracles for me. I recommend using 1, even 2 hotspares in your free slots.

    Reply
  • DD /

    26, 08 2021 10:11:09

    Great article!

    Reply
  • InuYasha /

    16, 01 2022 09:39:14

    I don’t know why there are so many negative comments here.
    As soon as I found out tht hot spare drive is SPINNING in a HP server, I moved to RAID6. Not only it wasted energy into heat, but have been worn out WITHOUT DATA. This is just terrible. Why in the hell did HP make it spin!? Also, I always set rebuild priority to maximum because the choice between performance and data loss is kind of obvious to me )

    Also, make your own CAPTCHA please!

    Reply