Webinars List

Welcome to our webinar section. Here you'll find everything from how Active-Active clusters work to why the ZFS system is so spectacular, all presented via video. If you find something that piques your interest; just click on the video and let our long-time experts explain said topic.

Open-E DSS V7 Active/Active Setup

EOL

Category: Other

Product: Open-E DSS V7

Language: English

Open-E DSS V7 Active/Active Setup

Jul 18, 2012

00:21:28

  • Overview and recommendations for iSCSI Active-Active Failover for Open-E DSS V7
  • Setup of the iSCSI Active-Active Failover
  • Configuration: Setting up iSCSI Active-Active Failover for Open-E DSS V7
  • Recommendations for the setup
Open-E DSS V6 iSCSI-Failover and MPIO with ESXi 5,0

EOL

Category: Other

Product: Open-E DSS V6

Language: English

Open-E DSS V6 iSCSI-Failover and MPIO with ESXi 5,0

Jul 17, 2012

00:21:03

Todd Maxwell - Director of Technical Sales

  • Setup the Open-E DSS V6 iSCSI Targets on both the Source and Destination
  • Configure the Open-E DSS V6 Auto Failover service
  • Enter the Virtual IP Addresses on both the Source and Destination
  • Connect the ESXi 5.0 via its initiator to the Open-E DSS V6 Virtual IP Addresses
  • Configure the MPIO settings on ESXi 5.0
Duplex Server (Zero Single Point of Failure HA Solution with Open-E DSS V6)

EOL

Category: Other

Product: Open-E DSS V6

Language: English

Duplex Server (Zero Single Point of Failure HA Solution with Open-E DSS V6)

Jul 10, 2012

01:03:13

Janusz Bak - Chief Technical Officer

  • How to configure DSS V6 iSCSI and NAS (NFS) Failover
  • How to connect iSCSI and NFS storage in ESXi 5.0
  • Demo of how DSS V6 iSCSI and NAS (NFS) Failover tolerates IO-errors
  • Duplex Server, a better Dual Controller
Storage Solutions for Configuring RAID array and iSCSI targets for performance with ESXi

EOL

Category: Other

Product: Open-E DSS V6

Language: English

Storage Solutions for Configuring RAID array and iSCSI targets for performance with ESXi

Jun 19, 2012

00:25:14

Greg Rafinski - Technical Systems Engineer

  • Configure RAID array and caching with and without BBU
  • Create iSCSI target
  • Tune the target (SCST) parameters from Open-E DSS V6 Console
  • Set the iSCSI initiator IP Adresses in VMware to connect to the Open-E DSS V6 target
  • Verify connectivity from the ESXi
Automatic Shutdown with SNMP powered UPS and Script Controlled shutdown

EOL

Category: Open-E DSS V6 Essentials

Product: Open-E DSS V6

Language: English

Automatic Shutdown with SNMP powered UPS and Script Controlled shutdown

Jun 12, 2012

00:35:05

Janusz Bak - Chief Technical Officer

  • How to configure Open-E DSS V6 with SNMP powered UPS (Uninterruptable Power Supply)
  • Power outage and Power restore Demo
  • How to configure and how to work with Open-E DSS V6 CLI/API
  • Script controlled system shutdown Demo
Configure Open-E DSS V6 for UPS Connectivity and Management

EOL

Category: Other

Product: Open-E DSS V6

Language: English

Configure Open-E DSS V6 for UPS Connectivity and Management

Jun 5, 2012

00:11:01

Todd Maxwell - Director of Technical Sales

  • Configure UPS connection from Open-E DSS V6 WebGUI
  • Verify Connection from PowerChute application
  • Verify continued power from UPS system
  • Issue graceful shutdown from UPS system
Solutions with Recovering Open-E DSS V6 after a Boot Drive Failure

EOL

Category: Other

Product: Open-E DSS V6

Language: English

Solutions with Recovering Open-E DSS V6 after a Boot Drive Failure

May 22, 2012

00:20:15

Todd Maxwell - Director of Technical Sales

  • Recommended boot media for DSS V6
  • Using the Filesystem Repair Utility
  • Replacing failed boot medium or have an alternative boot medium
  • Saving and Restoring the DSS V6 Settings and Configuration file
Storage Solutions with Recovering from a power failure with Auto Failover

EOL

Category: Other

Product: Open-E DSS V6

Language: English

Storage Solutions with Recovering from a power failure with Auto Failover

May 8, 2012

00:25:35

Todd Maxwell - Director of Technical Sales

  • Verify working failover pair
  • Simulate power failure on primary node
  • Verify secondary node becomes active node
  • Restore power to Primary, and boot
  • Restart failover service on Primary node
  • Sync volumes from secondary node to primary node, and failback to primary node
  • Verify primary node is active node
Storage Solutions with Re-Sizing iSCSI Logical Volumes with Auto Failover or Volume Replication

EOL

Category: Open-E DSS V6 Essentials

Product: Open-E DSS V6

Language: English

Storage Solutions with Re-Sizing iSCSI Logical Volumes with Auto Failover or Volume Replication

Apr 24, 2012

00:21:21

Greg Rafinski- Greg Rafinski - Technical Systems Engineer

  • Stop the Auto Failover Service on the Primary and Secondary
  • Stop the Volume Replication Tasks Disable the Replication feature on the iSCSI Logical Volumes
  • Modify both the Primary and Secondary iSCSI Logical Volumes to increase their size
  • Enable the Replication feature on the iSCSI Logical Volumes
  • Restart the Volume Replication Tasks
  • Restart the Auto Failover Service on the Primary and Secondary
Storage Solutions with Intel Servers

EOL

Category: Other

Product: Open-E DSS V6

Language: English

Storage Solutions with Intel Servers

Apr 10, 2012

00:40:32

Todd Maxwell - Director of Technical Sales

  • Introduction to the new Intel server Boards
  • Intel new line of RAID Controllers
  • Upgrades with Premium Features
  • SSD Cache 2.0 for Read and Write HOT Data