New H3C Technologies |
RAID P460-B4
|
up66, up70 - up71
|
-
|
Device and driver details
- Device id: 028F
- Vendor id: 9005
- Subdevice id: F461
- Subvendor id: 193D
System version |
Driver name |
Driver version |
Firmware |
Verified configuration |
Notes |
up71
|
smartpqi |
2.1.18-045 |
|
|
|
up70
|
smartpqi |
2.1.8-040 |
|
|
|
up66
|
smartpqi |
1.1.4-132 |
|
|
|
|
New H3C Technologies |
RAID P460-M2
|
up66, up70 - up71
|
-
|
Device and driver details
- Device id: 028F
- Vendor id: 9005
- Subdevice id: C460
- Subvendor id: 193D
System version |
Driver name |
Driver version |
Firmware |
Verified configuration |
Notes |
up71
|
smartpqi |
2.1.18-045 |
|
|
|
up70
|
smartpqi |
2.1.8-040 |
|
|
|
up66
|
smartpqi |
1.1.4-132 |
|
|
|
|
New H3C Technologies |
RAID P460-M4
|
up66, up70 - up71
|
-
|
Device and driver details
- Device id: 028F
- Vendor id: 9005
- Subdevice id: F460
- Subvendor id: 193D
System version |
Driver name |
Driver version |
Firmware |
Verified configuration |
Notes |
up71
|
smartpqi |
2.1.18-045 |
|
|
|
up70
|
smartpqi |
2.1.8-040 |
|
|
|
up66
|
smartpqi |
1.1.4-132 |
|
|
|
|
New H3C Technologies |
UN-NIC-ETH563T-sL-2P
|
up70 - up71
|
-
|
Device and driver details
- Device id: 1563
- Vendor id: 8086
- Subdevice id: 1011
- Subvendor id: 193D
System version |
Driver name |
Driver version |
Firmware |
Verified configuration |
Notes |
up71
|
ixgbe |
5.17.1 |
|
|
|
up70
|
ixgbe |
5.11.3 |
|
|
|
|
NEWNET |
Huawei RH2285-V2
|
-
|
up12
|
Device and driver details
- Device id: ffff
- Vendor id: ffff
- Subdevice id: ffff
- Subvendor id: ffff
System version |
Driver name |
Driver version |
Firmware |
Verified configuration |
Notes |
up12
CERTIFIED
|
NEWNET |
|
|
|
|
|
NEXT UPS Systems |
Logix RT 10000VA/9000W
|
up12, up16, up50, up53 - up54, up56 - up57, up60, up65 - up66
|
-
|
Device and driver details
- Device id: ffff
- Vendor id: ffff
- Subdevice id: ffff
- Subvendor id: ffff
System version |
Driver name |
Driver version |
Firmware |
Verified configuration |
Notes |
up71
|
UPS |
|
|
|
|
up70
|
UPS |
|
|
|
|
up66
|
UPS |
|
|
|
|
up65
|
UPS |
|
|
|
|
up60
|
UPS |
|
|
|
|
up57
|
UPS |
|
|
|
|
up56
|
UPS |
|
|
|
|
up54
|
UPS |
|
|
|
|
up53
|
UPS |
|
|
|
|
up50
|
UPS |
|
|
|
|
up16
|
UPS |
|
|
|
|
up12
|
UPS |
|
|
|
|
|
NEXT UPS Systems |
Logix RT 1000VA/900W
|
up12, up16, up50, up53 - up54, up56 - up57, up60, up65 - up66
|
-
|
Device and driver details
- Device id: ffff
- Vendor id: ffff
- Subdevice id: ffff
- Subvendor id: ffff
System version |
Driver name |
Driver version |
Firmware |
Verified configuration |
Notes |
up71
|
UPS |
|
|
|
|
up70
|
UPS |
|
|
|
|
up66
|
UPS |
|
|
|
|
up65
|
UPS |
|
|
|
|
up60
|
UPS |
|
|
|
|
up57
|
UPS |
|
|
|
|
up56
|
UPS |
|
|
|
|
up54
|
UPS |
|
|
|
|
up53
|
UPS |
|
|
|
|
up50
|
UPS |
|
|
|
|
up16
|
UPS |
|
|
|
|
up12
|
UPS |
|
|
|
|
|
NEXT UPS Systems |
Logix RT 1500VA/1350W
|
up12, up16, up50, up53 - up54, up56 - up57, up60, up65 - up66
|
-
|
Device and driver details
- Device id: ffff
- Vendor id: ffff
- Subdevice id: ffff
- Subvendor id: ffff
System version |
Driver name |
Driver version |
Firmware |
Verified configuration |
Notes |
up71
|
UPS |
|
|
|
|
up70
|
UPS |
|
|
|
|
up66
|
UPS |
|
|
|
|
up65
|
UPS |
|
|
|
|
up60
|
UPS |
|
|
|
|
up57
|
UPS |
|
|
|
|
up56
|
UPS |
|
|
|
|
up54
|
UPS |
|
|
|
|
up53
|
UPS |
|
|
|
|
up50
|
UPS |
|
|
|
|
up16
|
UPS |
|
|
|
|
up12
|
UPS |
|
|
|
|
|
NEXT UPS Systems |
Logix RT 2000VA/1800W
|
up12, up16, up50, up53 - up54, up56 - up57, up60, up65 - up66
|
-
|
Device and driver details
- Device id: ffff
- Vendor id: ffff
- Subdevice id: ffff
- Subvendor id: ffff
System version |
Driver name |
Driver version |
Firmware |
Verified configuration |
Notes |
up71
|
UPS |
|
|
|
|
up70
|
UPS |
|
|
|
|
up66
|
UPS |
|
|
|
|
up65
|
UPS |
|
|
|
|
up60
|
UPS |
|
|
|
|
up57
|
UPS |
|
|
|
|
up56
|
UPS |
|
|
|
|
up54
|
UPS |
|
|
|
|
up53
|
UPS |
|
|
|
|
up50
|
UPS |
|
|
|
|
up16
|
UPS |
|
|
|
|
up12
|
UPS |
|
|
|
|
|
NEXT UPS Systems |
Logix RT 3000VA/2700W
|
up12, up16, up50, up53 - up54, up56 - up57, up60, up65 - up66
|
-
|
Device and driver details
- Device id: ffff
- Vendor id: ffff
- Subdevice id: ffff
- Subvendor id: ffff
System version |
Driver name |
Driver version |
Firmware |
Verified configuration |
Notes |
up71
|
UPS |
|
|
|
|
up70
|
UPS |
|
|
|
|
up66
|
UPS |
|
|
|
|
up65
|
UPS |
|
|
|
|
up60
|
UPS |
|
|
|
|
up57
|
UPS |
|
|
|
|
up56
|
UPS |
|
|
|
|
up54
|
UPS |
|
|
|
|
up53
|
UPS |
|
|
|
|
up50
|
UPS |
|
|
|
|
up16
|
UPS |
|
|
|
|
up12
|
UPS |
|
|
|
|
|
NEXT UPS Systems |
Logix RT 6000VA/5400W
|
up12, up16, up50, up53 - up54, up56 - up57, up60, up65 - up66
|
-
|
Device and driver details
- Device id: ffff
- Vendor id: ffff
- Subdevice id: ffff
- Subvendor id: ffff
System version |
Driver name |
Driver version |
Firmware |
Verified configuration |
Notes |
up71
|
UPS |
|
|
|
|
up70
|
UPS |
|
|
|
|
up66
|
UPS |
|
|
|
|
up65
|
UPS |
|
|
|
|
up60
|
UPS |
|
|
|
|
up57
|
UPS |
|
|
|
|
up56
|
UPS |
|
|
|
|
up54
|
UPS |
|
|
|
|
up53
|
UPS |
|
|
|
|
up50
|
UPS |
|
|
|
|
up16
|
UPS |
|
|
|
|
up12
|
UPS |
|
|
|
|
|
NEXT UPS Systems |
Logix Tower 10000VA/9000W
|
up11 - up12, up16, up50, up53 - up54, up56 - up57, up60, up65 - up66
|
-
|
Device and driver details
- Device id: ffff
- Vendor id: ffff
- Subdevice id: ffff
- Subvendor id: ffff
System version |
Driver name |
Driver version |
Firmware |
Verified configuration |
Notes |
up71
|
UPS |
|
|
|
|
up70
|
UPS |
|
|
|
|
up66
|
UPS |
|
|
|
|
up65
|
UPS |
|
|
|
|
up60
|
UPS |
|
|
|
|
up57
|
UPS |
|
|
|
|
up56
|
UPS |
|
|
|
|
up54
|
UPS |
|
|
|
|
up53
|
UPS |
|
|
|
|
up50
|
UPS |
|
|
|
|
up16
|
UPS |
|
|
|
|
up12
|
UPS |
|
|
|
|
up11
|
UPS |
|
|
|
|
|
NEXT UPS Systems |
Logix Tower 1000VA/900W
|
up11 - up12, up16, up50, up53 - up54, up56 - up57, up60, up65 - up66
|
-
|
Device and driver details
- Device id: ffff
- Vendor id: ffff
- Subdevice id: ffff
- Subvendor id: ffff
System version |
Driver name |
Driver version |
Firmware |
Verified configuration |
Notes |
up71
|
UPS |
|
|
|
|
up70
|
UPS |
|
|
|
|
up66
|
UPS |
|
|
|
|
up65
|
UPS |
|
|
|
|
up60
|
UPS |
|
|
|
|
up57
|
UPS |
|
|
|
|
up56
|
UPS |
|
|
|
|
up54
|
UPS |
|
|
|
|
up53
|
UPS |
|
|
|
|
up50
|
UPS |
|
|
|
|
up16
|
UPS |
|
|
|
|
up12
|
UPS |
|
|
|
|
up11
|
UPS |
|
|
|
|
|
NEXT UPS Systems |
Logix Tower 2000VA/1800W
|
up11 - up12, up16, up50, up53 - up54, up56 - up57, up60, up65 - up66
|
-
|
Device and driver details
- Device id: ffff
- Vendor id: ffff
- Subdevice id: ffff
- Subvendor id: ffff
System version |
Driver name |
Driver version |
Firmware |
Verified configuration |
Notes |
up71
|
UPS |
|
|
|
|
up70
|
UPS |
|
|
|
|
up66
|
UPS |
|
|
|
|
up65
|
UPS |
|
|
|
|
up60
|
UPS |
|
|
|
|
up57
|
UPS |
|
|
|
|
up56
|
UPS |
|
|
|
|
up54
|
UPS |
|
|
|
|
up53
|
UPS |
|
|
|
|
up50
|
UPS |
|
|
|
|
up16
|
UPS |
|
|
|
|
up12
|
UPS |
|
|
|
|
up11
|
UPS |
|
|
|
|
|
NEXT UPS Systems |
Logix Tower 3000VA/2700W
|
up11 - up12, up16, up50, up53 - up54, up56 - up57, up60, up65 - up66
|
-
|
Device and driver details
- Device id: ffff
- Vendor id: ffff
- Subdevice id: ffff
- Subvendor id: ffff
System version |
Driver name |
Driver version |
Firmware |
Verified configuration |
Notes |
up71
|
UPS |
|
|
|
|
up70
|
UPS |
|
|
|
|
up66
|
UPS |
|
|
|
|
up65
|
UPS |
|
|
|
|
up60
|
UPS |
|
|
|
|
up57
|
UPS |
|
|
|
|
up56
|
UPS |
|
|
|
|
up54
|
UPS |
|
|
|
|
up53
|
UPS |
|
|
|
|
up50
|
UPS |
|
|
|
|
up16
|
UPS |
|
|
|
|
up12
|
UPS |
|
|
|
|
up11
|
UPS |
|
|
|
|
|
NEXT UPS Systems |
Logix Tower 6000VA/5400W
|
up11 - up12, up16, up50, up53 - up54, up56 - up57, up60, up65 - up66
|
-
|
Device and driver details
- Device id: ffff
- Vendor id: ffff
- Subdevice id: ffff
- Subvendor id: ffff
System version |
Driver name |
Driver version |
Firmware |
Verified configuration |
Notes |
up71
|
UPS |
|
|
|
|
up70
|
UPS |
|
|
|
|
up66
|
UPS |
|
|
|
|
up65
|
UPS |
|
|
|
|
up60
|
UPS |
|
|
|
|
up57
|
UPS |
|
|
|
|
up56
|
UPS |
|
|
|
|
up54
|
UPS |
|
|
|
|
up53
|
UPS |
|
|
|
|
up50
|
UPS |
|
|
|
|
up16
|
UPS |
|
|
|
|
up12
|
UPS |
|
|
|
|
up11
|
UPS |
|
|
|
|
|
NEXT UPS Systems |
Mantis RT 1100VA/880W
|
up12, up16, up50, up53 - up54, up56 - up57, up60, up65 - up66
|
-
|
Device and driver details
- Device id: ffff
- Vendor id: ffff
- Subdevice id: ffff
- Subvendor id: ffff
System version |
Driver name |
Driver version |
Firmware |
Verified configuration |
Notes |
up71
|
UPS |
|
|
|
|
up70
|
UPS |
|
|
|
|
up66
|
UPS |
|
|
|
|
up65
|
UPS |
|
|
|
|
up60
|
UPS |
|
|
|
|
up57
|
UPS |
|
|
|
|
up56
|
UPS |
|
|
|
|
up54
|
UPS |
|
|
|
|
up53
|
UPS |
|
|
|
|
up50
|
UPS |
|
|
|
|
up16
|
UPS |
|
|
|
|
up12
|
UPS |
|
|
|
|
|
NEXT UPS Systems |
Mantis RT 1500VA/1200W
|
up12, up16, up50, up53 - up54, up56 - up57, up60, up65 - up66
|
-
|
Device and driver details
- Device id: ffff
- Vendor id: ffff
- Subdevice id: ffff
- Subvendor id: ffff
System version |
Driver name |
Driver version |
Firmware |
Verified configuration |
Notes |
up71
|
UPS |
|
|
|
|
up70
|
UPS |
|
|
|
|
up66
|
UPS |
|
|
|
|
up65
|
UPS |
|
|
|
|
up60
|
UPS |
|
|
|
|
up57
|
UPS |
|
|
|
|
up56
|
UPS |
|
|
|
|
up54
|
UPS |
|
|
|
|
up53
|
UPS |
|
|
|
|
up50
|
UPS |
|
|
|
|
up16
|
UPS |
|
|
|
|
up12
|
UPS |
|
|
|
|
|
NEXT UPS Systems |
Mantis RT 2000VA/1600W
|
up12, up16, up50, up53 - up54, up56 - up57, up60, up65 - up66
|
-
|
Device and driver details
- Device id: ffff
- Vendor id: ffff
- Subdevice id: ffff
- Subvendor id: ffff
System version |
Driver name |
Driver version |
Firmware |
Verified configuration |
Notes |
up71
|
UPS |
|
|
|
|
up70
|
UPS |
|
|
|
|
up66
|
UPS |
|
|
|
|
up65
|
UPS |
|
|
|
|
up60
|
UPS |
|
|
|
|
up57
|
UPS |
|
|
|
|
up56
|
UPS |
|
|
|
|
up54
|
UPS |
|
|
|
|
up53
|
UPS |
|
|
|
|
up50
|
UPS |
|
|
|
|
up16
|
UPS |
|
|
|
|
up12
|
UPS |
|
|
|
|
|
NEXT UPS Systems |
Mantis RT 2500VA/2000W
|
up12, up16, up50, up53 - up54, up56 - up57, up60, up65 - up66
|
-
|
Device and driver details
- Device id: ffff
- Vendor id: ffff
- Subdevice id: ffff
- Subvendor id: ffff
System version |
Driver name |
Driver version |
Firmware |
Verified configuration |
Notes |
up71
|
UPS |
|
|
|
|
up70
|
UPS |
|
|
|
|
up66
|
UPS |
|
|
|
|
up65
|
UPS |
|
|
|
|
up60
|
UPS |
|
|
|
|
up57
|
UPS |
|
|
|
|
up56
|
UPS |
|
|
|
|
up54
|
UPS |
|
|
|
|
up53
|
UPS |
|
|
|
|
up50
|
UPS |
|
|
|
|
up16
|
UPS |
|
|
|
|
up12
|
UPS |
|
|
|
|
|
NEXT UPS Systems |
Mantis RT 3000VA/2400W
|
up12, up16, up50, up53 - up54, up56 - up57, up60, up65 - up66
|
-
|
Device and driver details
- Device id: ffff
- Vendor id: ffff
- Subdevice id: ffff
- Subvendor id: ffff
System version |
Driver name |
Driver version |
Firmware |
Verified configuration |
Notes |
up71
|
UPS |
|
|
|
|
up70
|
UPS |
|
|
|
|
up66
|
UPS |
|
|
|
|
up65
|
UPS |
|
|
|
|
up60
|
UPS |
|
|
|
|
up57
|
UPS |
|
|
|
|
up56
|
UPS |
|
|
|
|
up54
|
UPS |
|
|
|
|
up53
|
UPS |
|
|
|
|
up50
|
UPS |
|
|
|
|
up16
|
UPS |
|
|
|
|
up12
|
UPS |
|
|
|
|
|
NEXT UPS Systems |
Mantis RT 800VA/640W
|
up12, up16, up50, up53 - up54, up56 - up57, up60, up65 - up66
|
-
|
Device and driver details
- Device id: ffff
- Vendor id: ffff
- Subdevice id: ffff
- Subvendor id: ffff
System version |
Driver name |
Driver version |
Firmware |
Verified configuration |
Notes |
up71
|
UPS |
|
|
|
|
up70
|
UPS |
|
|
|
|
up66
|
UPS |
|
|
|
|
up65
|
UPS |
|
|
|
|
up60
|
UPS |
|
|
|
|
up57
|
UPS |
|
|
|
|
up56
|
UPS |
|
|
|
|
up54
|
UPS |
|
|
|
|
up53
|
UPS |
|
|
|
|
up50
|
UPS |
|
|
|
|
up16
|
UPS |
|
|
|
|
up12
|
UPS |
|
|
|
|
|
Nextron |
4U 36 disk Storageserver
|
up02
|
-
|
Device and driver details
- Device id: ffff
- Vendor id: ffff
- Subdevice id: ffff
- Subvendor id: ffff
System version |
Driver name |
Driver version |
Firmware |
Verified configuration |
Notes |
up02
|
Nextron |
|
|
|
|
|
Northern Telecom |
10/100BaseTX [RTL81xx]
|
up00 - up02, up05, up07, up10 - up12, up16, up50, up53 - up54, up56 - up57, up60, up65 - up66, up70 - up71
|
-
|
Device and driver details
- Device id: 1211
- Vendor id: 126c
- Subdevice id: ffff
- Subvendor id: ffff
System version |
Driver name |
Driver version |
Firmware |
Verified configuration |
Notes |
up71
|
8139too |
0.9.28 |
|
|
|
up70
|
8139too |
0.9.28 |
|
|
|
up66
|
8139too |
0.9.28 |
|
|
|
up65
|
8139too |
0.9.28 |
|
|
|
up60
|
8139too |
0.9.28 |
|
|
|
up57
|
8139too |
0.9.28 |
|
|
|
up56
|
8139too |
0.9.28 |
|
|
|
up54
|
8139too |
0.9.28 |
|
|
|
up53
|
8139too |
0.9.28 |
|
|
|
up50
|
8139too |
0.9.28 |
|
|
|
up16
|
8139too |
0.9.28 |
|
|
|
up12
|
8139too |
0.9.28 |
|
|
|
up11
|
8139too |
0.9.28 |
|
|
|
up10
|
8139too |
0.9.28 |
|
|
|
up07
|
8139too |
0.9.28 |
|
|
|
up05
|
8139too |
0.9.28 |
|
|
|
up02
|
8139too |
0.9.28 |
|
|
|
up01
|
8139too |
0.9.28 |
|
|
|
up00
|
8139too |
0.9.28 |
|
|
|
|
nVidia |
Apple iMac 9,1
|
up66, up70 - up71
|
-
|
Device and driver details
- Device id: 0AB0
- Vendor id: 10DE
- Subdevice id: CB79
- Subvendor id: 10DE
System version |
Driver name |
Driver version |
Firmware |
Verified configuration |
Notes |
up71
|
forcedeth |
FFFF |
|
|
|
up70
|
forcedeth |
FFFF |
|
|
|
up66
|
forcedeth |
FFFF |
|
|
|
|
nVidia |
CK804 Ethernet Controller
|
up00 - up02, up05, up07, up10 - up12, up16, up50, up53 - up54, up56 - up57, up60, up65 - up66, up70 - up71
|
-
|
Device and driver details
- Device id: 0057
- Vendor id: 10de
- Subdevice id: ffff
- Subvendor id: ffff
System version |
Driver name |
Driver version |
Firmware |
Verified configuration |
Notes |
up71
|
forcedeth |
FFFF |
|
|
|
up70
|
forcedeth |
|
|
|
|
up66
|
forcedeth |
FFFF |
|
|
|
up65
|
forcedeth |
|
|
|
|
up60
|
forcedeth |
|
|
|
|
up57
|
forcedeth |
|
|
|
|
up56
|
forcedeth |
|
|
|
|
up54
|
forcedeth |
|
|
|
|
up53
|
forcedeth |
|
|
|
|
up50
|
forcedeth |
|
|
|
|
up16
|
forcedeth |
|
|
|
|
up12
|
forcedeth |
|
|
|
|
up11
|
forcedeth |
|
|
|
|
up10
|
forcedeth |
|
|
|
|
up07
|
forcedeth |
|
|
|
|
up05
|
forcedeth |
|
|
|
|
up02
|
forcedeth |
|
|
|
|
up01
|
forcedeth |
|
|
|
|
up00
|
forcedeth |
|
|
|
|
|
nVidia |
CK804 Ethernet Controller
|
up00 - up02, up05, up07, up10 - up12, up16, up50, up53 - up54, up56 - up57, up60, up65 - up66, up70 - up71
|
-
|
Device and driver details
- Device id: 0056
- Vendor id: 10de
- Subdevice id: ffff
- Subvendor id: ffff
System version |
Driver name |
Driver version |
Firmware |
Verified configuration |
Notes |
up71
|
forcedeth |
FFFF |
|
|
|
up70
|
forcedeth |
|
|
|
|
up66
|
forcedeth |
FFFF |
|
|
|
up65
|
forcedeth |
|
|
|
|
up60
|
forcedeth |
|
|
|
|
up57
|
forcedeth |
|
|
|
|
up56
|
forcedeth |
|
|
|
|
up54
|
forcedeth |
|
|
|
|
up53
|
forcedeth |
|
|
|
|
up50
|
forcedeth |
|
|
|
|
up16
|
forcedeth |
|
|
|
|
up12
|
forcedeth |
|
|
|
|
up11
|
forcedeth |
|
|
|
|
up10
|
forcedeth |
|
|
|
|
up07
|
forcedeth |
|
|
|
|
up05
|
forcedeth |
|
|
|
|
up02
|
forcedeth |
|
|
|
|
up01
|
forcedeth |
|
|
|
|
up00
|
forcedeth |
|
|
|
|
|
nVidia |
CK804 Serial ATA Controller
|
up00 - up02, up05, up07, up10 - up12, up16, up50, up53 - up54, up56 - up57, up60, up65 - up66, up70 - up71
|
-
|
Device and driver details
- Device id: 0055
- Vendor id: 10de
- Subdevice id: ffff
- Subvendor id: ffff
System version |
Driver name |
Driver version |
Firmware |
Verified configuration |
Notes |
up71
|
sata_nv |
3.5 |
|
|
|
up70
|
sata_nv |
3.5 |
|
|
|
up66
|
sata_nv |
3.5 |
|
|
|
up65
|
sata_nv |
3.5 |
|
|
|
up60
|
sata_nv |
3.5 |
|
|
|
up57
|
sata_nv |
3.5 |
|
|
|
up56
|
sata_nv |
3.5 |
|
|
|
up54
|
sata_nv |
3.5 |
|
|
|
up53
|
sata_nv |
3.5 |
|
|
|
up50
|
sata_nv |
3.5 |
|
|
|
up16
|
sata_nv |
3.5 |
|
|
|
up12
|
sata_nv |
3.5 |
|
|
|
up11
|
sata_nv |
3.5 |
|
|
|
up10
|
sata_nv |
3.5 |
|
|
|
up07
|
sata_nv |
3.5 |
|
|
|
up05
|
sata_nv |
3.5 |
|
|
|
up02
|
sata_nv |
3.5 |
|
|
|
up01
|
sata_nv |
3.5 |
|
|
|
up00
|
sata_nv |
3.5 |
|
|
|
|
nVidia |
CK804 Serial ATA Controller
|
up00 - up02, up05, up07, up10 - up12, up16, up50, up53 - up54, up56 - up57, up60, up65 - up66, up70 - up71
|
-
|
Device and driver details
- Device id: 0054
- Vendor id: 10de
- Subdevice id: ffff
- Subvendor id: ffff
System version |
Driver name |
Driver version |
Firmware |
Verified configuration |
Notes |
up71
|
sata_nv |
3.5 |
|
|
|
up70
|
sata_nv |
3.5 |
|
|
|
up66
|
sata_nv |
3.5 |
|
|
|
up65
|
sata_nv |
3.5 |
|
|
|
up60
|
sata_nv |
3.5 |
|
|
|
up57
|
sata_nv |
3.5 |
|
|
|
up56
|
sata_nv |
3.5 |
|
|
|
up54
|
sata_nv |
3.5 |
|
|
|
up53
|
sata_nv |
3.5 |
|
|
|
up50
|
sata_nv |
3.5 |
|
|
|
up16
|
sata_nv |
3.5 |
|
|
|
up12
|
sata_nv |
3.5 |
|
|
|
up11
|
sata_nv |
3.5 |
|
|
|
up10
|
sata_nv |
3.5 |
|
|
|
up07
|
sata_nv |
3.5 |
|
|
|
up05
|
sata_nv |
3.5 |
|
|
|
up02
|
sata_nv |
3.5 |
|
|
|
up01
|
sata_nv |
3.5 |
|
|
|
up00
|
sata_nv |
3.5 |
|
|
|
|
nVidia |
CK8S Ethernet Controller
|
up00 - up02, up05, up07, up10 - up12, up16, up50, up53 - up54, up56 - up57, up60, up65 - up66, up70 - up71
|
-
|
Device and driver details
- Device id: 00e6
- Vendor id: 10de
- Subdevice id: ffff
- Subvendor id: ffff
System version |
Driver name |
Driver version |
Firmware |
Verified configuration |
Notes |
up71
|
forcedeth |
FFFF |
|
|
|
up70
|
forcedeth |
|
|
|
|
up66
|
forcedeth |
FFFF |
|
|
|
up65
|
forcedeth |
|
|
|
|
up60
|
forcedeth |
|
|
|
|
up57
|
forcedeth |
|
|
|
|
up56
|
forcedeth |
|
|
|
|
up54
|
forcedeth |
|
|
|
|
up53
|
forcedeth |
|
|
|
|
up50
|
forcedeth |
|
|
|
|
up16
|
forcedeth |
|
|
|
|
up12
|
forcedeth |
|
|
|
|
up11
|
forcedeth |
|
|
|
|
up10
|
forcedeth |
|
|
|
|
up07
|
forcedeth |
|
|
|
|
up05
|
forcedeth |
|
|
|
|
up02
|
forcedeth |
|
|
|
|
up01
|
forcedeth |
|
|
|
|
up00
|
forcedeth |
|
|
|
|
|
nVidia |
CK8S Ethernet Controller
|
up00 - up02, up05, up07, up10 - up12, up16, up50, up53 - up54, up56 - up57, up60, up65 - up66, up70 - up71
|
-
|
Device and driver details
- Device id: 00df
- Vendor id: 10de
- Subdevice id: ffff
- Subvendor id: ffff
System version |
Driver name |
Driver version |
Firmware |
Verified configuration |
Notes |
up71
|
forcedeth |
FFFF |
|
|
|
up70
|
forcedeth |
|
|
|
|
up66
|
forcedeth |
FFFF |
|
|
|
up65
|
forcedeth |
|
|
|
|
up60
|
forcedeth |
|
|
|
|
up57
|
forcedeth |
|
|
|
|
up56
|
forcedeth |
|
|
|
|
up54
|
forcedeth |
|
|
|
|
up53
|
forcedeth |
|
|
|
|
up50
|
forcedeth |
|
|
|
|
up16
|
forcedeth |
|
|
|
|
up12
|
forcedeth |
|
|
|
|
up11
|
forcedeth |
|
|
|
|
up10
|
forcedeth |
|
|
|
|
up07
|
forcedeth |
|
|
|
|
up05
|
forcedeth |
|
|
|
|
up02
|
forcedeth |
|
|
|
|
up01
|
forcedeth |
|
|
|
|
up00
|
forcedeth |
|
|
|
|
|
nVidia |
MCP04 Ethernet Controller
|
up00 - up02, up05, up07, up10 - up12, up16, up50, up53 - up54, up56 - up57, up60, up65 - up66, up70 - up71
|
-
|
Device and driver details
- Device id: 0038
- Vendor id: 10de
- Subdevice id: ffff
- Subvendor id: ffff
System version |
Driver name |
Driver version |
Firmware |
Verified configuration |
Notes |
up71
|
forcedeth |
FFFF |
|
|
|
up70
|
forcedeth |
|
|
|
|
up66
|
forcedeth |
FFFF |
|
|
|
up65
|
forcedeth |
|
|
|
|
up60
|
forcedeth |
|
|
|
|
up57
|
forcedeth |
|
|
|
|
up56
|
forcedeth |
|
|
|
|
up54
|
forcedeth |
|
|
|
|
up53
|
forcedeth |
|
|
|
|
up50
|
forcedeth |
|
|
|
|
up16
|
forcedeth |
|
|
|
|
up12
|
forcedeth |
|
|
|
|
up11
|
forcedeth |
|
|
|
|
up10
|
forcedeth |
|
|
|
|
up07
|
forcedeth |
|
|
|
|
up05
|
forcedeth |
|
|
|
|
up02
|
forcedeth |
|
|
|
|
up01
|
forcedeth |
|
|
|
|
up00
|
forcedeth |
|
|
|
|
|
nVidia |
MCP04 Ethernet Controller
|
up00 - up02, up05, up07, up10 - up12, up16, up50, up53 - up54, up56 - up57, up60, up65 - up66, up70 - up71
|
-
|
Device and driver details
- Device id: 0037
- Vendor id: 10de
- Subdevice id: ffff
- Subvendor id: ffff
System version |
Driver name |
Driver version |
Firmware |
Verified configuration |
Notes |
up71
|
forcedeth |
FFFF |
|
|
|
up70
|
forcedeth |
|
|
|
|
up66
|
forcedeth |
FFFF |
|
|
|
up65
|
forcedeth |
|
|
|
|
up60
|
forcedeth |
|
|
|
|
up57
|
forcedeth |
|
|
|
|
up56
|
forcedeth |
|
|
|
|
up54
|
forcedeth |
|
|
|
|
up53
|
forcedeth |
|
|
|
|
up50
|
forcedeth |
|
|
|
|
up16
|
forcedeth |
|
|
|
|
up12
|
forcedeth |
|
|
|
|
up11
|
forcedeth |
|
|
|
|
up10
|
forcedeth |
|
|
|
|
up07
|
forcedeth |
|
|
|
|
up05
|
forcedeth |
|
|
|
|
up02
|
forcedeth |
|
|
|
|
up01
|
forcedeth |
|
|
|
|
up00
|
forcedeth |
|
|
|
|
|
nVidia |
MCP04 Serial ATA Controller
|
up00 - up02, up05, up07, up10 - up12, up16, up50, up53 - up54, up56 - up57, up60, up65 - up66, up70 - up71
|
-
|
Device and driver details
- Device id: 003e
- Vendor id: 10de
- Subdevice id: ffff
- Subvendor id: ffff
System version |
Driver name |
Driver version |
Firmware |
Verified configuration |
Notes |
up71
|
sata_nv |
3.5 |
|
|
|
up70
|
sata_nv |
3.5 |
|
|
|
up66
|
sata_nv |
3.5 |
|
|
|
up65
|
sata_nv |
3.5 |
|
|
|
up60
|
sata_nv |
3.5 |
|
|
|
up57
|
sata_nv |
3.5 |
|
|
|
up56
|
sata_nv |
3.5 |
|
|
|
up54
|
sata_nv |
3.5 |
|
|
|
up53
|
sata_nv |
3.5 |
|
|
|
up50
|
sata_nv |
3.5 |
|
|
|
up16
|
sata_nv |
3.5 |
|
|
|
up12
|
sata_nv |
3.5 |
|
|
|
up11
|
sata_nv |
3.5 |
|
|
|
up10
|
sata_nv |
3.5 |
|
|
|
up07
|
sata_nv |
3.5 |
|
|
|
up05
|
sata_nv |
3.5 |
|
|
|
up02
|
sata_nv |
3.5 |
|
|
|
up01
|
sata_nv |
3.5 |
|
|
|
up00
|
sata_nv |
3.5 |
|
|
|
|
nVidia |
MCP04 Serial ATA Controller
|
up00 - up02, up05, up07, up10 - up12, up16, up50, up53 - up54, up56 - up57, up60, up65 - up66, up70 - up71
|
-
|
Device and driver details
- Device id: 0036
- Vendor id: 10de
- Subdevice id: ffff
- Subvendor id: ffff
System version |
Driver name |
Driver version |
Firmware |
Verified configuration |
Notes |
up71
|
sata_nv |
3.5 |
|
|
|
up70
|
sata_nv |
3.5 |
|
|
|
up66
|
sata_nv |
3.5 |
|
|
|
up65
|
sata_nv |
3.5 |
|
|
|
up60
|
sata_nv |
3.5 |
|
|
|
up57
|
sata_nv |
3.5 |
|
|
|
up56
|
sata_nv |
3.5 |
|
|
|
up54
|
sata_nv |
3.5 |
|
|
|
up53
|
sata_nv |
3.5 |
|
|
|
up50
|
sata_nv |
3.5 |
|
|
|
up16
|
sata_nv |
3.5 |
|
|
|
up12
|
sata_nv |
3.5 |
|
|
|
up11
|
sata_nv |
3.5 |
|
|
|
up10
|
sata_nv |
3.5 |
|
|
|
up07
|
sata_nv |
3.5 |
|
|
|
up05
|
sata_nv |
3.5 |
|
|
|
up02
|
sata_nv |
3.5 |
|
|
|
up01
|
sata_nv |
3.5 |
|
|
|
up00
|
sata_nv |
3.5 |
|
|
|
|
nVidia |
MCP2A Ethernet Controller
|
up00 - up02, up05, up07, up10 - up12, up16, up50, up53 - up54, up56 - up57, up60, up65 - up66, up70 - up71
|
-
|
Device and driver details
- Device id: 008c
- Vendor id: 10de
- Subdevice id: ffff
- Subvendor id: ffff
System version |
Driver name |
Driver version |
Firmware |
Verified configuration |
Notes |
up71
|
forcedeth |
FFFF |
|
|
|
up70
|
forcedeth |
|
|
|
|
up66
|
forcedeth |
FFFF |
|
|
|
up65
|
forcedeth |
|
|
|
|
up60
|
forcedeth |
|
|
|
|
up57
|
forcedeth |
|
|
|
|
up56
|
forcedeth |
|
|
|
|
up54
|
forcedeth |
|
|
|
|
up53
|
forcedeth |
|
|
|
|
up50
|
forcedeth |
|
|
|
|
up16
|
forcedeth |
|
|
|
|
up12
|
forcedeth |
|
|
|
|
up11
|
forcedeth |
|
|
|
|
up10
|
forcedeth |
|
|
|
|
up07
|
forcedeth |
|
|
|
|
up05
|
forcedeth |
|
|
|
|
up02
|
forcedeth |
|
|
|
|
up01
|
forcedeth |
|
|
|
|
up00
|
forcedeth |
|
|
|
|
|
nVidia |
MCP2A Ethernet Controller
|
up00 - up02, up05, up07, up10 - up12, up16, up50, up53 - up54, up56 - up57, up60, up65 - up66, up70 - up71
|
-
|
Device and driver details
- Device id: 0086
- Vendor id: 10de
- Subdevice id: ffff
- Subvendor id: ffff
System version |
Driver name |
Driver version |
Firmware |
Verified configuration |
Notes |
up71
|
forcedeth |
FFFF |
|
|
|
up70
|
forcedeth |
|
|
|
|
up66
|
forcedeth |
FFFF |
|
|
|
up65
|
forcedeth |
|
|
|
|
up60
|
forcedeth |
|
|
|
|
up57
|
forcedeth |
|
|
|
|
up56
|
forcedeth |
|
|
|
|
up54
|
forcedeth |
|
|
|
|
up53
|
forcedeth |
|
|
|
|
up50
|
forcedeth |
|
|
|
|
up16
|
forcedeth |
|
|
|
|
up12
|
forcedeth |
|
|
|
|
up11
|
forcedeth |
|
|
|
|
up10
|
forcedeth |
|
|
|
|
up07
|
forcedeth |
|
|
|
|
up05
|
forcedeth |
|
|
|
|
up02
|
forcedeth |
|
|
|
|
up01
|
forcedeth |
|
|
|
|
up00
|
forcedeth |
|
|
|
|
|
nVidia |
MCP51 Ethernet Controller
|
up00 - up02, up05, up07, up10 - up12, up16, up50, up53 - up54, up56 - up57, up60, up65 - up66, up70 - up71
|
-
|
Device and driver details
- Device id: 0269
- Vendor id: 10de
- Subdevice id: ffff
- Subvendor id: ffff
System version |
Driver name |
Driver version |
Firmware |
Verified configuration |
Notes |
up71
|
forcedeth |
FFFF |
|
|
|
up70
|
forcedeth |
|
|
|
|
up66
|
forcedeth |
FFFF |
|
|
|
up65
|
forcedeth |
|
|
|
|
up60
|
forcedeth |
|
|
|
|
up57
|
forcedeth |
|
|
|
|
up56
|
forcedeth |
|
|
|
|
up54
|
forcedeth |
|
|
|
|
up53
|
forcedeth |
|
|
|
|
up50
|
forcedeth |
|
|
|
|
up16
|
forcedeth |
|
|
|
|
up12
|
forcedeth |
|
|
|
|
up11
|
forcedeth |
|
|
|
|
up10
|
forcedeth |
|
|
|
|
up07
|
forcedeth |
|
|
|
|
up05
|
forcedeth |
|
|
|
|
up02
|
forcedeth |
|
|
|
|
up01
|
forcedeth |
|
|
|
|
up00
|
forcedeth |
|
|
|
|
|
nVidia |
MCP51 Ethernet Controller
|
up00 - up02, up05, up07, up10 - up12, up16, up50, up53 - up54, up56 - up57, up60, up65 - up66, up70 - up71
|
-
|
Device and driver details
- Device id: 0268
- Vendor id: 10de
- Subdevice id: ffff
- Subvendor id: ffff
System version |
Driver name |
Driver version |
Firmware |
Verified configuration |
Notes |
up71
|
forcedeth |
FFFF |
|
|
|
up70
|
forcedeth |
|
|
|
|
up66
|
forcedeth |
FFFF |
|
|
|
up65
|
forcedeth |
|
|
|
|
up60
|
forcedeth |
|
|
|
|
up57
|
forcedeth |
|
|
|
|
up56
|
forcedeth |
|
|
|
|
up54
|
forcedeth |
|
|
|
|
up53
|
forcedeth |
|
|
|
|
up50
|
forcedeth |
|
|
|
|
up16
|
forcedeth |
|
|
|
|
up12
|
forcedeth |
|
|
|
|
up11
|
forcedeth |
|
|
|
|
up10
|
forcedeth |
|
|
|
|
up07
|
forcedeth |
|
|
|
|
up05
|
forcedeth |
|
|
|
|
up02
|
forcedeth |
|
|
|
|
up01
|
forcedeth |
|
|
|
|
up00
|
forcedeth |
|
|
|
|
|
nVidia |
MCP51 Serial ATA Controller
|
up00 - up02, up05, up07, up10 - up12, up16, up50, up53 - up54, up56 - up57, up60, up65 - up66, up70 - up71
|
-
|
Device and driver details
- Device id: 0267
- Vendor id: 10de
- Subdevice id: ffff
- Subvendor id: ffff
System version |
Driver name |
Driver version |
Firmware |
Verified configuration |
Notes |
up71
|
sata_nv |
3.5 |
|
|
|
up70
|
sata_nv |
3.5 |
|
|
|
up66
|
sata_nv |
3.5 |
|
|
|
up65
|
sata_nv |
3.5 |
|
|
|
up60
|
sata_nv |
3.5 |
|
|
|
up57
|
sata_nv |
3.5 |
|
|
|
up56
|
sata_nv |
3.5 |
|
|
|
up54
|
sata_nv |
3.5 |
|
|
|
up53
|
sata_nv |
3.5 |
|
|
|
up50
|
sata_nv |
3.5 |
|
|
|
up16
|
sata_nv |
3.5 |
|
|
|
up12
|
sata_nv |
3.5 |
|
|
|
up11
|
sata_nv |
3.5 |
|
|
|
up10
|
sata_nv |
3.5 |
|
|
|
up07
|
sata_nv |
3.5 |
|
|
|
up05
|
sata_nv |
3.5 |
|
|
|
up02
|
sata_nv |
3.5 |
|
|
|
up01
|
sata_nv |
3.5 |
|
|
|
up00
|
sata_nv |
3.5 |
|
|
|
|
nVidia |
MCP51 Serial ATA Controller
|
up00 - up02, up05, up07, up10 - up12, up16, up50, up53 - up54, up56 - up57, up60, up65 - up66, up70 - up71
|
-
|
Device and driver details
- Device id: 0266
- Vendor id: 10de
- Subdevice id: ffff
- Subvendor id: ffff
System version |
Driver name |
Driver version |
Firmware |
Verified configuration |
Notes |
up71
|
sata_nv |
3.5 |
|
|
|
up70
|
sata_nv |
3.5 |
|
|
|
up66
|
sata_nv |
3.5 |
|
|
|
up65
|
sata_nv |
3.5 |
|
|
|
up60
|
sata_nv |
3.5 |
|
|
|
up57
|
sata_nv |
3.5 |
|
|
|
up56
|
sata_nv |
3.5 |
|
|
|
up54
|
sata_nv |
3.5 |
|
|
|
up53
|
sata_nv |
3.5 |
|
|
|
up50
|
sata_nv |
3.5 |
|
|
|
up16
|
sata_nv |
3.5 |
|
|
|
up12
|
sata_nv |
3.5 |
|
|
|
up11
|
sata_nv |
3.5 |
|
|
|
up10
|
sata_nv |
3.5 |
|
|
|
up07
|
sata_nv |
3.5 |
|
|
|
up05
|
sata_nv |
3.5 |
|
|
|
up02
|
sata_nv |
3.5 |
|
|
|
up01
|
sata_nv |
3.5 |
|
|
|
up00
|
sata_nv |
3.5 |
|
|
|
|
nVidia |
MCP55 Ethernet
|
up00 - up02, up05, up07, up10 - up12, up16, up50, up53 - up54, up56 - up57, up60, up65 - up66, up70 - up71
|
-
|
Device and driver details
- Device id: 0373
- Vendor id: 10de
- Subdevice id: ffff
- Subvendor id: ffff
System version |
Driver name |
Driver version |
Firmware |
Verified configuration |
Notes |
up71
|
forcedeth |
FFFF |
|
|
|
up70
|
forcedeth |
|
|
|
|
up66
|
forcedeth |
FFFF |
|
|
|
up65
|
forcedeth |
|
|
|
|
up60
|
forcedeth |
|
|
|
|
up57
|
forcedeth |
|
|
|
|
up56
|
forcedeth |
|
|
|
|
up54
|
forcedeth |
|
|
|
|
up53
|
forcedeth |
|
|
|
|
up50
|
forcedeth |
|
|
|
|
up16
|
forcedeth |
|
|
|
|
up12
|
forcedeth |
|
|
|
|
up11
|
forcedeth |
|
|
|
|
up10
|
forcedeth |
|
|
|
|
up07
|
forcedeth |
|
|
|
|
up05
|
forcedeth |
|
|
|
|
up02
|
forcedeth |
|
|
|
|
up01
|
forcedeth |
|
|
|
|
up00
|
forcedeth |
|
|
|
|
|
nVidia |
MCP55 Ethernet
|
up00 - up02, up05, up07, up10 - up12, up16, up50, up53 - up54, up56 - up57, up60, up65 - up66, up70 - up71
|
-
|
Device and driver details
- Device id: 0372
- Vendor id: 10de
- Subdevice id: ffff
- Subvendor id: ffff
System version |
Driver name |
Driver version |
Firmware |
Verified configuration |
Notes |
up71
|
forcedeth |
FFFF |
|
|
|
up70
|
forcedeth |
|
|
|
|
up66
|
forcedeth |
FFFF |
|
|
|
up65
|
forcedeth |
|
|
|
|
up60
|
forcedeth |
|
|
|
|
up57
|
forcedeth |
|
|
|
|
up56
|
forcedeth |
|
|
|
|
up54
|
forcedeth |
|
|
|
|
up53
|
forcedeth |
|
|
|
|
up50
|
forcedeth |
|
|
|
|
up16
|
forcedeth |
|
|
|
|
up12
|
forcedeth |
|
|
|
|
up11
|
forcedeth |
|
|
|
|
up10
|
forcedeth |
|
|
|
|
up07
|
forcedeth |
|
|
|
|
up05
|
forcedeth |
|
|
|
|
up02
|
forcedeth |
|
|
|
|
up01
|
forcedeth |
|
|
|
|
up00
|
forcedeth |
|
|
|
|
|
nVidia |
MCP55 SATA Controller
|
up00 - up02, up05, up07, up10 - up12, up16, up50, up53 - up54, up56 - up57, up60, up65 - up66, up70 - up71
|
-
|
Device and driver details
- Device id: 037f
- Vendor id: 10de
- Subdevice id: ffff
- Subvendor id: ffff
System version |
Driver name |
Driver version |
Firmware |
Verified configuration |
Notes |
up71
|
sata_nv |
3.5 |
|
|
|
up70
|
sata_nv |
3.5 |
|
|
|
up66
|
sata_nv |
3.5 |
|
|
|
up65
|
sata_nv |
3.5 |
|
|
|
up60
|
sata_nv |
3.5 |
|
|
|
up57
|
sata_nv |
3.5 |
|
|
|
up56
|
sata_nv |
3.5 |
|
|
|
up54
|
sata_nv |
3.5 |
|
|
|
up53
|
sata_nv |
3.5 |
|
|
|
up50
|
sata_nv |
3.5 |
|
|
|
up16
|
sata_nv |
3.5 |
|
|
|
up12
|
sata_nv |
3.5 |
|
|
|
up11
|
sata_nv |
3.5 |
|
|
|
up10
|
sata_nv |
3.5 |
|
|
|
up07
|
sata_nv |
3.5 |
|
|
|
up05
|
sata_nv |
3.5 |
|
|
|
up02
|
sata_nv |
3.5 |
|
|
|
up01
|
sata_nv |
3.5 |
|
|
|
up00
|
sata_nv |
3.5 |
|
|
|
|
nVidia |
MCP55 SATA Controller
|
up00 - up02, up05, up07, up10 - up12, up16, up50, up53 - up54, up56 - up57, up60, up65 - up66, up70 - up71
|
-
|
Device and driver details
- Device id: 037e
- Vendor id: 10de
- Subdevice id: ffff
- Subvendor id: ffff
System version |
Driver name |
Driver version |
Firmware |
Verified configuration |
Notes |
up71
|
sata_nv |
3.5 |
|
|
|
up70
|
sata_nv |
3.5 |
|
|
|
up66
|
sata_nv |
3.5 |
|
|
|
up65
|
sata_nv |
3.5 |
|
|
|
up60
|
sata_nv |
3.5 |
|
|
|
up57
|
sata_nv |
3.5 |
|
|
|
up56
|
sata_nv |
3.5 |
|
|
|
up54
|
sata_nv |
3.5 |
|
|
|
up53
|
sata_nv |
3.5 |
|
|
|
up50
|
sata_nv |
3.5 |
|
|
|
up16
|
sata_nv |
3.5 |
|
|
|
up12
|
sata_nv |
3.5 |
|
|
|
up11
|
sata_nv |
3.5 |
|
|
|
up10
|
sata_nv |
3.5 |
|
|
|
up07
|
sata_nv |
3.5 |
|
|
|
up05
|
sata_nv |
3.5 |
|
|
|
up02
|
sata_nv |
3.5 |
|
|
|
up01
|
sata_nv |
3.5 |
|
|
|
up00
|
sata_nv |
3.5 |
|
|
|
|
nVidia |
MCP61 Ethernet
|
up00 - up02, up05, up07, up10 - up12, up16, up50, up53 - up54, up56 - up57, up60, up65 - up66, up70 - up71
|
-
|
Device and driver details
- Device id: 03ef
- Vendor id: 10de
- Subdevice id: ffff
- Subvendor id: ffff
System version |
Driver name |
Driver version |
Firmware |
Verified configuration |
Notes |
up71
|
forcedeth |
FFFF |
|
|
|
up70
|
forcedeth |
|
|
|
|
up66
|
forcedeth |
FFFF |
|
|
|
up65
|
forcedeth |
|
|
|
|
up60
|
forcedeth |
|
|
|
|
up57
|
forcedeth |
|
|
|
|
up56
|
forcedeth |
|
|
|
|
up54
|
forcedeth |
|
|
|
|
up53
|
forcedeth |
|
|
|
|
up50
|
forcedeth |
|
|
|
|
up16
|
forcedeth |
|
|
|
|
up12
|
forcedeth |
|
|
|
|
up11
|
forcedeth |
|
|
|
|
up10
|
forcedeth |
|
|
|
|
up07
|
forcedeth |
|
|
|
|
up05
|
forcedeth |
|
|
|
|
up02
|
forcedeth |
|
|
|
|
up01
|
forcedeth |
|
|
|
|
up00
|
forcedeth |
|
|
|
|
|
nVidia |
MCP61 Ethernet
|
up00 - up02, up05, up07, up10 - up12, up16, up50, up53 - up54, up56 - up57, up60, up65 - up66, up70 - up71
|
-
|
Device and driver details
- Device id: 03ee
- Vendor id: 10de
- Subdevice id: ffff
- Subvendor id: ffff
System version |
Driver name |
Driver version |
Firmware |
Verified configuration |
Notes |
up71
|
forcedeth |
FFFF |
|
|
|
up70
|
forcedeth |
|
|
|
|
up66
|
forcedeth |
FFFF |
|
|
|
up65
|
forcedeth |
|
|
|
|
up60
|
forcedeth |
|
|
|
|
up57
|
forcedeth |
|
|
|
|
up56
|
forcedeth |
|
|
|
|
up54
|
forcedeth |
|
|
|
|
up53
|
forcedeth |
|
|
|
|
up50
|
forcedeth |
|
|
|
|
up16
|
forcedeth |
|
|
|
|
up12
|
forcedeth |
|
|
|
|
up11
|
forcedeth |
|
|
|
|
up10
|
forcedeth |
|
|
|
|
up07
|
forcedeth |
|
|
|
|
up05
|
forcedeth |
|
|
|
|
up02
|
forcedeth |
|
|
|
|
up01
|
forcedeth |
|
|
|
|
up00
|
forcedeth |
|
|
|
|
|
nVidia |
MCP61 Ethernet
|
up00 - up02, up05, up07, up10 - up12, up16, up50, up53 - up54, up56 - up57, up60, up65 - up66, up70 - up71
|
-
|
Device and driver details
- Device id: 03e6
- Vendor id: 10de
- Subdevice id: ffff
- Subvendor id: ffff
System version |
Driver name |
Driver version |
Firmware |
Verified configuration |
Notes |
up71
|
forcedeth |
FFFF |
|
|
|
up70
|
forcedeth |
|
|
|
|
up66
|
forcedeth |
FFFF |
|
|
|
up65
|
forcedeth |
|
|
|
|
up60
|
forcedeth |
|
|
|
|
up57
|
forcedeth |
|
|
|
|
up56
|
forcedeth |
|
|
|
|
up54
|
forcedeth |
|
|
|
|
up53
|
forcedeth |
|
|
|
|
up50
|
forcedeth |
|
|
|
|
up16
|
forcedeth |
|
|
|
|
up12
|
forcedeth |
|
|
|
|
up11
|
forcedeth |
|
|
|
|
up10
|
forcedeth |
|
|
|
|
up07
|
forcedeth |
|
|
|
|
up05
|
forcedeth |
|
|
|
|
up02
|
forcedeth |
|
|
|
|
up01
|
forcedeth |
|
|
|
|
up00
|
forcedeth |
|
|
|
|
|
nVidia |
MCP61 Ethernet
|
up00 - up02, up05, up07, up10 - up12, up16, up50, up53 - up54, up56 - up57, up60, up65 - up66, up70 - up71
|
-
|
Device and driver details
- Device id: 03e5
- Vendor id: 10de
- Subdevice id: ffff
- Subvendor id: ffff
System version |
Driver name |
Driver version |
Firmware |
Verified configuration |
Notes |
up71
|
forcedeth |
FFFF |
|
|
|
up70
|
forcedeth |
|
|
|
|
up66
|
forcedeth |
FFFF |
|
|
|
up65
|
forcedeth |
|
|
|
|
up60
|
forcedeth |
|
|
|
|
up57
|
forcedeth |
|
|
|
|
up56
|
forcedeth |
|
|
|
|
up54
|
forcedeth |
|
|
|
|
up53
|
forcedeth |
|
|
|
|
up50
|
forcedeth |
|
|
|
|
up16
|
forcedeth |
|
|
|
|
up12
|
forcedeth |
|
|
|
|
up11
|
forcedeth |
|
|
|
|
up10
|
forcedeth |
|
|
|
|
up07
|
forcedeth |
|
|
|
|
up05
|
forcedeth |
|
|
|
|
up02
|
forcedeth |
|
|
|
|
up01
|
forcedeth |
|
|
|
|
up00
|
forcedeth |
|
|
|
|
|
nVidia |
MCP61 SATA Controller
|
up00 - up02, up05, up07, up10 - up12, up16, up50, up53 - up54, up56 - up57, up60, up65 - up66, up70 - up71
|
-
|
Device and driver details
- Device id: 03f7
- Vendor id: 10de
- Subdevice id: ffff
- Subvendor id: ffff
System version |
Driver name |
Driver version |
Firmware |
Verified configuration |
Notes |
up71
|
sata_nv |
3.5 |
|
|
|
up70
|
sata_nv |
3.5 |
|
|
|
up66
|
sata_nv |
3.5 |
|
|
|
up65
|
sata_nv |
3.5 |
|
|
|
up60
|
sata_nv |
3.5 |
|
|
|
up57
|
sata_nv |
3.5 |
|
|
|
up56
|
sata_nv |
3.5 |
|
|
|
up54
|
sata_nv |
3.5 |
|
|
|
up53
|
sata_nv |
3.5 |
|
|
|
up50
|
sata_nv |
3.5 |
|
|
|
up16
|
sata_nv |
3.5 |
|
|
|
up12
|
sata_nv |
3.5 |
|
|
|
up11
|
sata_nv |
3.5 |
|
|
|
up10
|
sata_nv |
3.5 |
|
|
|
up07
|
sata_nv |
3.5 |
|
|
|
up05
|
sata_nv |
3.5 |
|
|
|
up02
|
sata_nv |
3.5 |
|
|
|
up01
|
sata_nv |
3.5 |
|
|
|
up00
|
sata_nv |
3.5 |
|
|
|
|